| Item | Parameter | |
| Model | MD001 | |
| DC Output | Rated Output | 120V /100A |
| Constant power | 120V | |
| Output voltage range | 30~120V | |
| Output current range | 0~100A | |
| Output overvoltage protection | 130±5V | |
| Output undervoltage alarm | 30V±2V | |
| Short circuit protection | Overload fold backand short circuit proof | |
| Voltage stabilized accuracy | ≤±0.5% | |
| Load sharing | ≤±3% | |
| Max. startup overshoot | ≤±1% | |
| Current stabilized accuracy | ≤±1% | |
| Startup Time | Normally 3s≤t≤8s | |
| Efficiency | Highest efficiency>96%, rated efficiency>95% | |
| AC input | Input voltage | 260VAC~485VAC(3phase without neutral) |
| Input frequency | 45Hz~65Hz | |
| THD | ≤5% | |
| Number of items | Three phase + protection ground | |
| Power factor | PF ≥ 0.99 | |
| Max. input current | <31A | |
| Input undervoltage protection | 255V ±5V | |
| Input overvoltage protection | 490V ±5V | |
| Input Power Derating | 260V ±5V<Vin<304V±5V, linearderating from 100% to 50%. | |
| Communication &alarm | Communication | CAN&485 |
| Max. Number of parallel machines | 60pcs | |
| Alarm and status | Report to monitor via CAN bus or 485 bus ; Display it on LED panel | |
| Operating environment | Operating temperature | -30℃~70℃,derating from 55℃ |
| Over temperature protection | On temperature >70°C±4°C or <-40°C±4°C, module will shut down automatically | |
| Storage temperature | - 40℃~85℃ | |
| Humidity | ≤95% RH, without condensation | |
| Pressure/Altitude | 79kPa~106kPa/2000m | |
| Physical characteristics | Acoustic Noise | <55dB |
| Cooling | Fan cooling | |
| Dimensions | 219.5mm (H) *84mm (W) *395mm (D) | |
| Weight | <10Kg | |
| MTBF | >120000 hrs(40℃) | |